Swap a faulty integrated LED downlight for a matching one, working safely with the power off and the ceiling checked first.
Like-for-like replacement of a light fitting is not notifiable under Part P. It only becomes notifiable if you install a new circuit or move the fitting to a new location. In bathroom zones the replacement must keep the same or better IP (water) rating.
If the ceiling below is a fire-separating floor between flats or storeys, Building Regs Part B requires the fire separation to be maintained - use a fire-rated hood or cap over the fitting.
BS 7671 (the IET Wiring Regulations) requires a Class II double-insulated fitting where there's no earth conductor at the point - don't fit a metal-bodied light in that situation.